MASA International Co., Ltd.

TEL: +81-75-874-4340 Weekdays 9:00–18:00 (JST)

CATALOGCatalog

MIC-100X / High-Speed Photosynthesis Rate Measuring Device

The MIC-100X high-speed photosynthesis rate measuring device is a groundbreaking instrument specialized for measuring the photosynthetic capacity of plant leaves, enabling much faster measurement times.

It's ideal for collecting large volumes of comparative data across many samples. Once complete, measurement data (CO2, temperature, humidity, and calculated photosynthetic rate) is stored on the SD card in Excel format. Simply carry the SD card to freely analyze and edit the data on your own PC.

※ Click a catalog image to enlarge it.

Key Features

POINT 01

High-Speed Measurement

We've achieved a quarter of the actual measurement time of conventional devices (about 30 seconds per sample). Within a measurement window suited to plant evaluation (roughly 4 hours), you can now collect far more data. Using Auto Mode, measurement in about 20 seconds per leaf is also possible.

POINT 02

Lightweight

We've achieved about two-thirds the weight of conventional devices (total weight approx. 7kg), reducing the burden on field workers and boosting efficiency.

POINT 03

Affordable

By focusing solely on measuring photosynthetic rate and adopting a new measurement method (a semi-open CO2 sensor built into a closed leaf chamber directly beneath the leaf surface, with photosynthetic rate displayed via a predictive calculation model), we've achieved a significant cost reduction.

Specifications

Control Unit, Measurement Head, and More

Measurement Range CO2 0–1500ppm
Humidity 10–90%RH (no condensation)
Temperature 10–50°C
Measurement Mode Precision measurement (Manual Mode)
High-speed measurement (Auto Mode)
Measured Values Photosynthetic rate (A)
400ppm-corrected photosynthetic rate (A')
Measurement Accuracy (Photosynthetic Rate) Repeatability *1 ±10% / standard deviation ±3σ
Chamber Flow Rate During measurement Sealed
Otherwise 600–1000mL/min at 20°C
Size & Weight
(incl. standard battery)
Control unit 215(W) × 175(D) × 290(H)mm, approx. 4.5kg
Measurement head 90(W) × 350(D) × 170(H)mm, approx. 2.3kg
Cable 1.5m, approx. 0.3kg
LED Artificial Light Source
(fixed output)
4 white LEDs, 8 red LEDs
PPFD: 1200μmol m-2s-1 *5
Aperture: 20mm × 30mm
Display 4.3-inch TFT LCD
Atmospheric Pressure Correction None
Operating Ambient Temperature 10–40°C
Power Supply & Continuous Use Time 3+ hours with the standard 6.4Ah lithium-ion battery
Ambient Zero-Gas Unit 2 soda lime columns for CO2 removal *2
1 silica gel column for humidity control *2
Standard Accessories Carrying case, strap, battery, battery charger, SD card (8GB), CD (data-binding software), 2 gaskets, free band, tripod mounting screw block
Optional Accessories Calibration standard gas *3 Zero gas (N2)
Span gas (CO2)
Pressure regulator
High-capacity 12.8Ah lithium-ion battery *4

*1 Repeatability accuracy applies to a photosynthetic rate range of 10–40μmol m-2s-1.

*2 The ambient zero-gas unit is built into the control unit and is used for zero-gas calibration during ordinary comparative measurement. Depending on usage, replace it after about 30,000 measurements or 6 months, whichever comes first.

*3 The calibration standard gas comes as small cylinders for zero gas and span gas. Please calibrate periodically.

*4 If continuous use exceeds 3 hours, we recommend the high-capacity lithium-ion battery, which allows about 6 hours of continuous use.

*5 An ambient-light type and a 2-step switchable-intensity type (700 / 1200μmol m-2s-1) are also available as options.

Consultations & Quotes for MIC-100X

Feel free to contact us about adoption, demo requests, spec questions, and more.

NEW Transpiration Measurement option now available

▲